Thats not right if it is a 3-phase motor, perhaps the wires are switched, but for a regular hayward pump (residential) 3-phase power would be very rare. Look for a clogged pump impeller, clogged basket, or other obstruction before the filter, or an air leak in front of the pump, or a broken pressure gauge, but the seal should not be related, unless it was literally gushing gallons of water. Is it possible that the filter is the problem? Hello we have a Hyward Power Flo Matrix 1 HP pump for a 15 foot above ground pool the pump runs however only seems to fill the strainer basket half way and is very noisy (like its struggling to get enough water in) the pressure guage on sand filter reads 15 psi and everything has been cleaned and new o-rings installed all around. If your pump is made of plastic, it must be the bearings, failing so hard that it is causing the motor to overheat. Sometimes you can pull out the clog with needle nose pliers. Hi there if you are hearing no noise from the pump at all, shut off power and check the wiring connections at the pump, switch/timer, and breaker, to be sure wires are making good terminal contact. It looks like no one has them in Stock and if I cant filter the pool, then it wont be usable. You could also use a Hayward 24 sand filter, item E3324. Reconnect the pipes and test it out! If power is tested at these points, I would check the motor terminals. One of them was arguably the best-constructed route from London [Marylebone] to Manchester. Harwil type flow switches can become damaged over time and will need replacement at some point. If the breaker is GFI, those are very sensitive, could be a bad breaker too. I checked the voltage at the back of the motor and have 240 volts. If the blower prover switch does not close after the blower starts the control will stop the ignition trial go into lockout. Like it is getting through the shaft seal but the seal is brand new.. any thoughts? If still nothing, look for damage in the rear of the motor, something burned, melted, loose, or pinched or cut wires. Is this rectifier bad? Hi Ryan, it possibly could be a problem with running two extension cords, also could be voltage fluctuation, or loose terminal connections, or just a pump going bad. Most above ground pool pumps are not self-priming, and mot inground pumps are self-priming. Sir, I have a Hayward Ecostar 3400 variable speed pump and will not run anymore. Hi Davy, Im trying to remove the impeller from a Hayward 1 HP superpump. 4. Replace with the exact same capacitor (look at the MFD rating printed on the capacitor). Third guess is closed or broken valves, clogged filter, clogged impeller, or other obstruction preventing water flow. Then you can pump out the water with a submersible pump, or depending on the surface material and design of your water feature, it may be better for the surfaces not to drain it, but to treat it with chemicals and put a heavy cover over it, where possible. Thanks Davy. Hello. Now that i have my new liner in and pool is filled i started adding chemicals to the pool and i went to turn the switch on and there is nothing happening with the motor. hi I followed the set up directions on my new sp1580lx pump and it keeps tripping the breaker. Hi there. Now I am looking to replace the old filter. What should I do? If you want, you can remove the capacitor and wrap it in a heavy cloth, or rubber sheet just in case. I have called a repair company since the pump is under warranty and they told me that it is almost NEVER the pump and therefore if it is something else I will have to pay $89/hour for their serviceso I was hoping to exhaust all other possibilities before coughing up the moneyCan you recommend any tests that I can do? I have a Hayward power-flow matrix pump with hayward preflex extended cycle D.E. Humming Motor: If the pump motor makes a humming sound when starting up, you likely have a clogged impeller. It is being practiced by thousands of pool owners just like you. Yes this pool was install without GFCI protection, (of course we will installing an equipment ground and GFCI Breakers.) Check the incoming motor voltage to be sure it is correct, too low or too high can cause problems. It is a H400FDN series. Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. When in front of the pump, problems like a clogged impeller, air leak into the pump, or clogged skimmer line, or low water these will produce filter pressure lower than normal (on the filter pressure gauge). But the process seems to take way too long. My first thought is that the breaker may be too small for the amount of amps needed to start each piece of equipment. It could also be due to the air intake, or the filter pressure, Water around the base, check the motor bolts or seal plate clamp for tightness on the seal plate o-ring, and check drain plugs for tightness, but most likely its coming from around the outlet pipe, and dripping down to the base, or from the shaft seal, which leaks directly mid bottom, where motor connects. Theres a few ideas to check, good luck! If the shaft is free turning, but the pump does not turn on, check power connections. Hi David, that would be my first guess, assuming that the power leads are tight, and connections or switches arent loose in the back. For AquaRite, move the switch from auto to off and check all of the readings. Should it be very hot to touch or is this an indicator for a capacitor problem? Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. Thanks again! Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? If your sweeper has a booster pump, could be a problem with a clogged impeller, or air leak into the pump, or some other pump issue. Is there a thicker housing oring that could be installed to fix the leak? Hi there, I have a 2-speed (hi and low) Hayward pump. Have no power at all going to my control panel. 908-355-7995. Hi Jodi, perhaps the rod is not threaded all the way into the base, or there may be debris under the rod, preventing it from going down fully. Hi Mark, in looking at the owners manual https://www.intheswim.com/images/PDFs/E1964-Manual.pdf perhaps there is a minimum speed setting that is set to high, or the programming Day/Time/Speed is set up to permit high speed only? Is this a ground issue or something else? I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. ), or 4) loose suction side valves, I have a hayward 1081 century with 3/4 hp motor with top mounted capacitor. Automation, Learn About If it reoccurs, you may have some pipe problems, such as a collapsed flexible PVC pipe on the skimmer. If the impeller spins freely, does that mean the shaft is spinning freely or do I need to try to turn it from the back of the motor? Ohms reading should be between 0.5 and 1.0 ohms max. Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? Backwash several times to remove as much DE powder as possible, and then add 4 cups of DE powder for every 10 sq ft of filter surface area (see filter label if unsure). Hi again, I dont have a shaft seal replacement video, but there are many on youtube. Or could it be a dirty motor or ground wire that isnt connected well enough? Any idea of the problem?? "@type": "Organization",
If that is what is happening to you Im sorry, but your motor is probably gasping its last breaths. The pump has power, turns on, and seals are tight, however it will not cycle the water. could be cord problem, too. I also tried it in a different place same outcome.What am I doing wrong? Sometimes pump lids can also warp or even the pump housing or internals, in cases where the pump got REALLY hot, but that is rare, but if the cause, youd need some new parts, or new pump. At first, the pump would only hum and not work. I let the pump cool down, then reset the thermal switch and it runs for another hour and shuts off again.The wiring is the same and it doesnt trip the breaker switch. "datePublished": "2/24/2015",
Not it says drivererror pump stalled. 20amp fuse is not blown. "identifier": ""
Hi Mike, when there is no wiring diagram printed on the motor label or above the nameplate, indicating High/Low Voltage wiring specs, then the motor is not reversible. Check for possible disruption inside of the flow T. Installation requires 12 inches of straight pipe before the flow switch. On initial trial for ignition. I have a Hayward HeatPro model HP21104T. "width": "611",
But most plastic impellers are closed nowadays, with non-visible vanes. We just opened our pool up cleaned everything out put new D.E. Other causes of high pressure could be unrelated to the pump size, such as an obstruction or restriction on the return line, or a partially closed valve, or plugged wall returns, or eyeball fittings in the pool that are too small. Could it have shut it self off from overheating? Whats the best and safest way to troubleshoot? You can also check that the phone cord wire is plugged into the interface, on underside. crooked house (2008 trailer) It doesnt mean it is ready to go at 230. The issue continue to happen so I called a pool repair technician and he came out and verified that the filter was put together properly and also replaced the O-rings in the backwash valve. Display seems to be reading correctly and shows the cell is not generating. Either way, when a DE filter clogs up quickly, it is either not enough DE powder being used, or the grids (flex tubes for Perflex) are clogged with mineral scale or oily deposits. Troubleshooting your Hayward salt system - YouTube Does the LED light turn off after 60 seconds? I have a t-15 cell. Air leaks can occur over time, the most often areas are a loose pump lid, unlubed pump lid oring, or my favorite, the loose threaded fitting that brings water into the pump. Not normal, but cant see a reason why that would cause the seal to fail. What is the incoming voltage on a H-150 pool/spa heater ? If you vacuumed the floc residue into the filter, you should be able to remove most of it with a thorough backwashing of 5 minutes or so. But higher pressure and no suction, that means an obstruction PAST the impeller. The pump never turns off but it should pull the water through constantly. Hi Mark, hard to say if it does not display any error code, the caution symbol on a Hayward Heater is usually accompanied by an error code, LO being the most common, for low water flow. It has been in operation since mid May without and incident before yesterday. Hi Steven, probably the breaker tripped or the GFCI test button popped out due to some water touching some wire. Thanks, good question. This year, I noticed at times that the flow rate on low speed is less than it was last year. Just replaced our pool pump, Hayward 1 hp self priming, super pump. Inspect the centrifugal switch on the end of the shaft and the stationary switch mounted at 6 oclock and contacting the central centrifugal switch make sure all are intact and tightly secured, and not bent, broken or affected by mud or insects. Or the filter cartridge may need to be replaced, and is clogged with minerals/dirt/oil, and creating the high pressure itself. Motor may still be good. Not sure power goes to the pump. Have you checked the cells voltage, amperage, or done anything other troubleshooting? I just replaced the seal and all of the gaskets along with carefully cleaning the grooves that the gaskets rest in and greasing them thoroughly with Jacks. Attached please find a copy of the Aqua Plus Operation Manual Please note Section - Configuration Menu Items, Cell Type Selection, page 16. If you had a multiport valve, you could put it on recirculate and verify, but since perflex have no such valve, the only other test would be to actually plumb around the filter, by installing a bypass valve and line, or just temporarily routing plumbing around the filter, to bypass the filter completely. I replaced the entire pump motor and the same thing happened. of and in " a to was is ) ( for as on by he with 's that at from his it an were are which this also be has or : had first one their its new after but who not they have LibriVox is a hope, an experiment, and a question: can the net harness a bunch of volunteers to help bring books in the Dec 14, 2021. No matter what setting I put it in its backwashing the sand into the skimmer. Zeolite Market Share In 2022 | Top Players [ Shanghai Hengye, Zeotech Corp, Blue Pacific Minerals (BPM), UOP (Honeywell) ] In-Depth Analysis, Forecast to 2027 with Top Countries Data | A Answered on 5/26/2022 by InyoPools Product Specialist Craig C.. Hello J. Camfrog Pro Extreme Atau Gold - Camfrog Indonesia. Exterior Wall Covering Materials, I have a Hayward Power-Flo Matrix and seems to be working fine when it is running the pool. So, I dont think you can use this motor, (sorry), unless you are able to add another 110V wire, and run both connected wires from a Double pole breaker. hayward blue essence troubleshootingventure pal backpack field operation 40l hayward blue essence troubleshooting Hi Frank, so it ran for weeks or more on 115V, when set to accept 230V, and then it started overheating, and then ran great for about a month, but now it makes no noise at all. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. Try to spin the impeller by hand, to be sure that the motor shaft spins freely and is not bound-up. Washed out the 4 Large cartridge filters before startup. Otherwise I would say the switch that changes from low to high may be stuck, from corrosion, insects or breakage. "datePublished": "3/27/2015",
If there is input power, the fuse may have blown. When you see a quick spurt or spray of water when the pump shuts off, this is an area where air is entering the system, and causing priming problems. Inspect the gasket as well, for nicks, dry-rot or other damage that may affect the seal. Incorrect sizing can cause multiple problems, including low water flow. Hi Ric, is the SF service factor rating the same on both motors (new and old)? Hi Joe, could be a relay clicking, if you have a controller attached to the system, look for burnt or melted hi-speed relay. Backwash works but not filter.. we took it apart and replaced the housing gasket, diffuser gasket and seal shaft. Whats that part called in case I do break it? Hayward pumps come in a variety of horsepowers, voltages and speeds. voltage reachs the stationary switch. Corrosion inside the plug or socket. Hi Tom, If the filter and pump are located below the water level of the pond, you could open up the pump lid or remove the filter drain plug, and the pond should gravity drain. Step 2: Verify the accuracy of the salt readings (2700-3400 ppm) with an independent test kit or by taking a water sample to your local pool store for testing. Hi Tony, there could be a short in the motor, or loose wires connecting to the capacitor, or if the capacitor you are replacing with is not the correct capacitor, or if the centrifugal or stationary switches are not releasing the capacitor, due to loose or misaligned switches, or loose wires, or wires shorting out by touching other wires or the motor casing, or crimped wires give a good look around the back of the motor, and try another capacitor, maybe call Hayward and ask for the correct capacitor MFD number for your horsepower of Northstar. Do you feel my capacitor is going bad or my motor? Hi Rudy, clicking on/off sounds like the switch in the rear of the motor, you may find either the centrifugal switch (dead center) or the stationary switch (6 oclock), may not be fully disengaging, or may be loose or bent. I have a Hayward Perflex DE filter brand new last year. Any advice?? Hi Larry, When DE is coming back into the pool, its usually: Have zero skills with pool pump filter motors or basically anything associated. Products, Learn About dr myers ultrasound. GFCIs are sensitive, but for a reason. Have an old Hayward super II pump, worked fine last fall, this spring at startup very low volume. Product Type Model Name Select Model # Third possibility is just that the pump capacitor is bad, if the motor wont turn over, wont spin. It probably just needs to dry out, but breakers that trip do need to be fully turned to Off, before they can be turned back On again. If not the skimmer being blocked, then its an air leak BEFORE the pump impeller. Well, the good news is you are at the right spot and youre definitely not alone. Interesting however that you say the pump works on backwash, but not on filter? Aquarite is not powering up at all. I have no display showing. It seems the pump is more powerful than last year ? I disconnected it and plugged the Aquatrol in alone; that worked fine. If the clock motor is dead, you can replace just the motor, but most people replace the entire mechanism. Hi Martha, open the air bleeder, perhaps there is a lot of air in the tank, drawn in by the pump. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
Most likely, and unfortunately yes. I have a new above ground pool with a Hayword pump. The new pump then starts to overheat and it shuts off. I only rotated the one piece how can the screws not go right back in? Do you know what the suggested torque is for the housing cap screws? The most common areas for an air leak are the pump lid (is it as tight as possible? When this has been corrected, shut the power down to the pump and rest it after 15 minutes. I have great circulation, but I the problem is after the pump runs for around a half hour on the filter setting it barely has any force coming out of the jet. This quick spray of water when you shut the pump off, as you have experienced, are a useful tool in locating an air leak on a pump. The new pump is exact same model and when not connected to system it spins and runs fine. I would suggest replacing the pump with the same exact pump, which is matched to your filter size presumably. When pump start it work fine but after few hours water stop moving. Hayward Aquarite T-CELL-5 | 20,000G Replacement Cell - Salt Pool Store Suggestions on what to do next. I Have an electric Hayward pool heater that comes on automatically when temperatures drop and then runs 3 or 4 hours. Reattach capacitor, replace rear cover and test motor again. They are higher voltage or whateverbut could that be the problem? It would run fine. registration, authorized You can remove the wires and call your local Electric Motor Repair Shop, and see if they have this capacitor in stock, just read them the MFD number range printed on the side of the black cylinder. Does it really need to be replaced? the 4th wire, the high speed wire. I cannot locate the model # on either but believe the filter is a c250. Loose wiring, or broken wires, or wires nearly touching each other, and arcing. New motors are always set to accept 230V when shipped, but can fall out of adjustment, or if you are using 115V, then the motor (if reversible voltage motor), the motor can be switched to accept 115V. If the gears are not moving, either the motor for the clock is dead, or insects or lizard is stuck in the gears, or the breaker is tripped or off, or the breaker is bad. I opened the control panel during a rain storm (down pour) to turn off the filter. What does F5 mean? We have a variable speed pump for filter and a single stage pump for cleaner. Also use a rag to clean the surfaces that mate on the pump body. So,as a first step to see if the power outlet is broken or not, I tried to charge my cellphone to the power outlet and it is charging. Replace with exact duplicated MFD numbers. When he went to turn the pool back on it made a slight humming noise like it was trying to come back on but it wouldnt turn on. hayward super pump C48L2N134B1. We are a registered 501(c)3 non-profit that is funded by user donations. I noticed the on/off switch seemed loose and when I took of the end case, the male disconnect to the switch was burned out. Issues with Hayward Blue Essence | Trouble Free Pool Hi Scott, if the cracked case seal has any possibility of letting water in, maybe you can silicone it to seal it up. Hi Mark, should it be 115V? I did find the black power wire lose on the pump when checking the wire connections, so I reconnected it but to no avail. Anyone have this issue or have any recommendations? Press and hold the diagnostic button for 3 to 5 seconds. well, possibly it just needs to dry out. Hopefully the GFI then holds. Not sure what to call it voltage selector perhaps? hayward blue essence troubleshooting - Habikalli.com Thanks, Steve DeGray. Hi Mike, if there are power outages, mechanical timeclocks need to be reset. If so, shut off power and see if the motor shaft will spin. While you have the nest assy out of the tank, after hosing it off, soak it in a DE filter cleaner, to remove any scale and oils. Flow switches require a minimum flow fate of 11 gallons per minute to stay consistently closed, Water temperature is below 50 degrees F. (The cell output scales back to 20% once it reaches 60 degrees F and shuts off at 50 degrees F.). If the pump makes no noise at all, turn on power, and with a multi meter, check the power at the pump, switch/timer and breaker, the problem lies where the power dies. dont know if the pump went bad already. Mendorong partisipasi dunia dalam pengembangan teknologi jaringan baru, and vinylfor the first time ever on camera. ), or the valves that are before the pump. The pool is only 15 months old and I have not had any problems since getting it installed May 2017, other than a small water leak coming from the non suction side of the pump. What can I do? I have a Hayward North Star that I rebuilt with new motor, shaft seal, all new rubber seals, impeller, and diffuser. External bypass is out of adjustment. Pull out the pump basket and reach back thru the volute to feel the impeller with your fingertips (pump off, lol), if you feel any debris, reach in with needlenose pliers, or pull apart the pump and ream the impeller vanes with a length of wire or a small screwdriver. After Irma came through, we were without power for a week, the pump wont run on low speed and when it runs at high speed, it overheats after about an hour and shuts off. Also check that wires are tightly attached, at breaker, timer and pump. Ive been told my Hayward Vsp has been shutting itself off for low power issues, even though no power issues are present. Occasionally the salt level on the Hayward Aqua Rite may not match the actual salt level of the pool. ' Have a Hayward pump for above ground pool.when I start the pump it works properly and then itll stop pumping water. Second thought is are the pipes plumbed into the valve correct? A pump that simply wont start is a frustrating problem. Hayward Pool Heater Troubleshooting - In The Swim Pool Blog Look for 4 other bolts, or a clamp band, to pull the motor/impeller out of the wet end, or the pump housing. {
If you have power coming into the motor, but no pump noise, check (Power off) that wire connections are tight, and inspect the wire for breaks or damage. I think I have some air leakage on my supply side of my Hayward Super Pump. Scrape out the old gasket with a sharp screwdriver and glue a new one in place with dabs of superglue gasket flat side down, ridged side up. Work through the chart below if your heater displays the following error codes. Or, soak them in a TSP solution (1 lb of TSP in 5 gals warm water), followed by a soaking in an acid solution, 1 gallon acid added to 4 gallons of water. "name": "In The Swim",
What should i do now? If thats not the air leak, check the pump lid o-ring, Superpump square lid rings sometimes get twisted easily. Any idea why this might be happening? Everything seems to be set up correctly on the filter and motor. I replaced the breaker and electrical plug which showed some damage but motor does not start and breaker still tripping I am a novice with in ground pools, but is the pool motor supposed to run continuously?